Equipment

CETAL-PW – CETAL PW Laser Facility
  • 1 PW laser system – Thales, France
  • Beam transport – Ardop, France
  • Interaction Chamber – Astra Gemini, RAL UK
  • Femtosecond laser beam characterization devices
  • Electron beam detectors, X-ray detectors

More info ...

PW Laser System
LaMP – Laser material processing
Integrated system for laser macroprocessing
Lasers:
  • TruDisk 3001
  • TruPulse 62
  • TruMicro 7050

Workstations:

  • TruLaser Cell 3010
  • TruLaser Robot 5020

More info ...

3D laser lithography
Photonic Profesional from Nanoscribe – Germany
  • fs laser Toptica - 120 fs
  • Zeiss inverted microscope
  • PIMars piezo stage 300x300x300 µm3
  • Translation stage 100x100 mm2
  • Microscope Objectives: 100x oil, 100x DiLL, 63x, 20x

More info ...
 

www.nanoscribe.de
Pulse laser deposition system
  • Laser source 1 Coherent: 355 nm
  • Laser source 2 Lumera 1064, 532, 355 nm
  • Multitarget vacuum chamber
  • RHEED

More info ...
 

Laser microprocessing system integrated by INFLPR
  • Laser source Lumera HyperRapid 50
  • Wavelengths 1064, 532, 355 nm
  • Two Axis, Linear-Motor Stage, PlanarDL 200XY Aerotech
  • 3 laser scanning heads for 3 wavelengths
  • Laser fume extractor.

More info ...

Sample preparation in cleanroom
  • Plasma cleaner
  • Utrasonic bath 0.5 l
  • Spin coater 6000 rpm
  • Hot plate up to 400 oC
  • Fume hood 1800 x 700 mm2
  • Trinocular microscope (objectives 4x 10x 40x)

More info ...

;

Tunable CW CO2 laser

  • Laser power : 1 kW
  • Wavelength: 9.2-11.2 µm
  • Beam diameter : 13 mm diameter

More info ...
 

Laser synthesis of functional nanomaterials 

  • Nd:YAG solid state laser source Brilliant B 1064, 532, and 266 nm emission wavelengths
  • Laser pulse energy control and measurement system
  • Laser induced forward transfer / direct laser irradiation workstation
  • Laser beam homogenizer
  • Micrometric XYZ positioning stage
  • Computers and software for automated processing
  • Combined pulsed laser deposition / matrix assisted pulsed laser evaporation equipment
  • Spin coater
  • Ceramic top hotplate magnetic stirrer
  • Gas exhauster hood
  • Analytical micro-balance
  • Ultrasonic bath with heating function
  • UV-Vis spectrophotometer
  • DC and pulsed electrical measurement system
  • Computing workstation for numerical simulations 

More info ...

Atomic Absorption Spectroscopy
  • Measurement Modes: flame absorption, flame emission, graphite furnace, hydride generation.
  • Wavelength Range: 190 - 900 nm
  • Wavelength Range: 190 - 900 nm
  • Room temperature - 3000 oC
  • Available lamps: Ag, As, Ca, Cd, Co, Cr, Cu, Fe, Hg, Mg, Mn, Na, Ni, Pb, Se, Sn, Sr, Zn..

More info ...

PhIL – Photonic Investigations

Optical Frequency Synthesizer
FC1500-250 from MenloSystems , Germany

  • Laser head M-Comb
  • Amplifier for offset beat generation P250-XPS-WG :
  • Amplifier for second harmonic generation 780 nm P250-SHG
  • Repetition rate 250 MHz
  • Tuning range linear stage > 2 MHz
  • Tuning rate piezo 3500 Hz

More info ...

Tunable picosecond laser
NKT SuperExtreme EXW-4

  • Tunability: 450-2400 nm
  • SuperK filter: 450-800 nm
  • Repetition rate: 78 MHz
  • Polarization: unpolarized
  • Beam output: gaussian, single mode
  • Total power: 2W

More info ...

 THz Pulsed Imaging and Spectroscopy - TPS Spectra 3000 from TeraView, UK
  • Terahertz transmission and reflectance measurements on solids, liquids, suspensions, slurries and films
  • Spectral Range – 0.06 THz to 4 THz (2 cm-1 - 120 cm-1)
  • ATR modules for optimized measurements on as little as 1 mg solid sample
  • RIM module for reflectance mapping
  • XY transmittance module for transmittance mapping
  • GaAs antenna used for emitter and detector for ambient temperature operation
More info ...
Double Monochromator Spectroradiometer OL 750 from Gooch&Housego, Orlando - USA      
 
  • Spectral range: 200- 30000 nm
Configurations:
  • Source Spectral Analysis
  • Detector Responsivity
  • Diffuse Spectral Reflectance
  • Spectral Transmittance @ 0°
  • Transmittance Goniometer
  • Specular Reflectance Goniometer
  • BRDF

More info ...
 

High Speed NVS Spectroradiometer OL 770 from Gooch&Housego, Orlando - USA

  • NVIS Indicator Lamp & Filter Testing

More info ...

Si Microbolometer Beam Imaging Camera WinCamD-FIR2-16-HR from DataRay Inc., USA
  • 2 to 16 µm Si microbolometer
  • 640 x 480, 13.4 x 10.8 mm active area
  • 17 µm pixels
  • Port-powered USB 2.0; flexible 3 m cable, no power brick
  • 14-bit ADC, 4 MB image buffer & on-board microprocessor
  • 10 ms time constant
  • No chopper – measure pulsed or CW beams
  • Room temperature – no cooling required
More info ...
Tunable Quantum Laser Cascade Systems MonoLux-XX from Pranalytica, USA
  • QCW and CW operation
  • Centre wavelengths: 3.8 µm, 4.5 µm , 5.2 µm, 7.4 µm, 9.5 µm and 10.4 µm, depending on the laser head
  • scan over selected tuning range with selected step size and scan speed
More info ...

Tunable ns Laser Sunlite EX OPO with FX-1 from Continuum, USA

  • Laser  tunability with no degeneracy gap : 445 nm - 1750 nm
  • FX-1 frequency doubling option for 222.5 nm to 450 nm operation
  • Pump Energy  350 mJ
  • Linewidth 0.075 cm-1
  • Pulsewidth  3-6 ns
  • Energy at peak  50 mJ  at 550nm

More info ... 

Shock and vibration system  ES-6-230 from Dongling Vibration Test Instrument Co,Ltd, China

  • Frequency range : 5-3000 Hz
  • Max Displacement : 50 mm
  • Max Acceleration : 100 G
  • Max  velocity  : 1.8 m/s
  • Supports shocks and vibrations in both horizontal and vertical axes

 

More info ... 

Laser Breakdown Spectroscopy System  LIBS-6 from Applied Photoncs, UK

  • Wavelength Range : 200-900 nm
  • Laser : Quantel Big Sky CFR 1064 nm
  • Max Energy : 197 mJ
  • Pulse frequency : 1-20 Hz
  • Contains 3 axis translation stage with video camera
  • Sample Chamber dimensions 260 x 260 x 320 mm
  • Accessories: Modular sample chambers designed for liquids, solids and powders.

More info ... 

Dispersive Raman Microscope JASCO NRS-7200

  • 532 nm, 633 nm si 785 nm lasers
  • Maximum resolution: 0.3 cm-1
  • Measurement range: 5-8000 cm-1
  • XYZ automatic stage with 100 nm resolution
  • Aberation-corrected Czerny-Turner monochromator (f=500 mm)

More info ...

 Photonic investigation of bio-materials

  • Shimadzu 8400S Fourier Transform Infrared Spectroscopy.
  • Shimadzu AIM - 8800 infrared microscope.
  • Optical  Microscope Leica DM4000 B LED,
  • Vertical laminar airflow cabinet BSC-EN I – II.
  • FX1200-x safety cabinet MRC.

More info ...

Optical data link

Wireless communication, designed to serve short distance point-to-point or multipoint configuration.

More info ...

Chemistry Laboratory
Provides the infrastructure for all chemical operations in a safe enviroment both for product and operator.

List of equipments:
Peristaltic pump
Oven
Analytical balance

More info ...